Wiring and Cabling
Brittle gold plating on contacts
Exterior
cracking was observed on 20 and 22 gauge pin and socket
contacts. The contacts are constructed of gold plate
over copper plate; SEM/EDS did not reveal any nickel
underplate although a flash coat may be present. This
condition occurred for all crimp tools used at this
facility on these contacts. Brittle gold plating was
the suspected cause.
Reference :
NASA-STD-8739.4
19.6 Inspection Criteria
2. Rejection Criteria. The following are unsatisfactory
conditions and shall be cause for rejection:
c. Crimped Connections (1) Metal ferrules crimped with
improper alignment. (2) Cracks in crimp barrel. (3)
Birdcaging of conductor. (4) Wire strands not visible
in inspection hole. (5) Peeling or flaking of plating
on contact. (6) Damaged or deformed crimp contact. (7)
Crimp indents not located in the correct area on the
contact. (8) Tarnished, corroded, or contaminated crimp
contact. (9) Improper insulation clearance. (10) Insulation
whiskers that extend into the crimp barrel.
|