Wiring and Cabling
Shield damage on connector
Improper
handling resulted in this connector harness assembly
failure. The flight cable assembly was apparently pulled
and twisted resulting in the separation of the copper
shield that covered the wires as well as the internal
breaking of wires .
Reference
:
NASA-STD-8739.4
16.3 Completed Interconnecting Harness and Cable
Storage Protection 2. Overstressing and excessive
flexing of wires shall be avoided during connector cleaning
and mating/demating operations. This is especially important
for solder-type connectors.
2. Rejection Criteria. The following are unsatisfactory
conditions and shall be cause for rejection: e. Cable
and Harness Assemblies: (4) Cracked, charred, or split
insulation
19.6
Inspection Criteria
Rejection Criteria. The following are unsatisfactory
conditions and shall be cause for rejection: (2) Nicked,
gouged, damaged, or severed conductors. (3) Frayed conductor
strands.
|